Metal strapping on a PVC conduit | Information by Electrical ...
Jun 2, 2024 · Ok so in the 2017 NEC it only mentions the concern on of expansion and contraction of pvc pipe with metal straps? When mounting pvc pipe in outdoor conditions it’s best to use plastic …
PVC conduit vs plumbing pipe | Information by Electrical Professionals ...
Sep 29, 2021 · Both are schedule 40 PVC. I’ve seen the same BS about plumbing pipe is thicker but 2 minutes checking the actual specs shows something very different…actually the same. But the big …
Pull string in PVC | Information by Electrical Professionals for ...
Nov 19, 2010 · What do you guys/gals use for a pull string in pvc pipe. I have run into this on our last 2 jobs where we have sucked in a greenlee string or mule tape (the rope thats flat and light weight) …
HDPE vs PVC Schedule 80 - Mike Holt's Forum
Aug 2, 2018 · I have always specified PVC Schedule 80 for outdoor underground installations. Contractor is asking to use HDPE, would this substitution be inferior, equivalent, or superior? Thank you
Threading PVC in the Field | Information by Electrical Professionals ...
Sep 19, 2013 · Hi all, I have a question, Is threading electrical PVC conduit (Sch 40 and/or Sch 80) in the field an approved/listed means for construction? I personally have never seen this done in the …
PVC schedule 80 or 40 | Information by Electrical Professionals for ...
Feb 18, 2005 · Re: PVC schedule 80 or 40 Reading UL 651 Schedule 40 & 80 Rigid PVC conduit: "Schedule 80 rigid PVC conduit are for use wherever schedule 40 conduit may be used and in …
Transition of RGS conduit to PVC conduit | Information by Electrical ...
Jan 8, 2019 · I have a situation where there is a transition of RGS Metal conduit from above ground to PVC conduit Under ground. The spec says to use " a threaded PVC to rigid metal conduit adapter" …
Underground Wiring in PVC Conduit | Information by Electrical ...
Aug 22, 2011 · When running wires underground through PVC conduit to feed a garage, is THHN or THWN the proper type to use? Suppose a garage is to be wired with a subpanel fed from the house …
PVC sechdule 80 or 40 - Mike Holt's Forum
Jan 25, 2018 · I have a job in which i like to use PVC but not sure which sechdule since from electric utilty to panel board goes underground and above ground outside in weather. Can I install PVC …
PVC - Cement and Primer | Information by Electrical Professionals for ...
Jun 16, 2007 · With only pvc cement, I can almost always remove the fitting by cutting it with a hacksaw, and then break it away from the conduit with a screwdriver. When we use primer, this becomes …